HP Smart array CLI commands
HP Smart array CLI commands (these should apply to any system with the CLI installed)
Show configuration
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl all show config |
Controller status
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl all show status |
Show detailed controller information for all controllers
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl all show detail |
Show detailed controller information for controller in slot 0
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 show detail |
Rescan for New Devices
1 |
/opt/hp/hpssacli/bin/hpssacli rescan |
Physical disk status
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show status |
Show detailed physical disk information
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show detail |
Logical disk status
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld all show status |
View Detailed Logical Drive Status
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 show |
Create New RAID 0 Logical Drive
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0 |
Create New RAID 1 Logical Drive
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1 |
Create New RAID 5 Logical Drive
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5 |
Delete Logical Drive
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 delete |
Add New Physical Drive to Logical Volume
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7 |
Add Spare Disks
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7 |
Enable Drive Write Cache
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=enable |
Disable Drive Write Cache
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=disable |
Erase Physical Drive
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd 2I:1:6 modify erase |
Turn on Blink Physical Disk LED
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=on |
Turn off Blink Physical Disk LED
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=off |
Modify smart array cache read and write ratio (cacheratio=readratio/writeratio)
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify cacheratio=100/0 |
Enable smart array write cache when no battery is present (No-Battery Write Cache option)
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify nbwc=enable |
Disable smart array cache for certain Logical Volume
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable |
Enable smart array cache for certain Logical Volume
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable |
Enable SSD Smart Path
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=enable |
Disable SSD Smart Path
1 |
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=disable |